AA S200/ CZ200 Quick fill with Bar manometr

New

Quick Fill is a device that replaces the original air tube plug. This quick fill has both gauge and filling hole for pin and there is no need to air tube unscrew the body of the rifle. We are also selling Filling adapter .

More details

62,00 €

- +

  • High precion of regulation

  • Unique technologic solution

  • You buy directly from the manufacturer

  • 2 years warranty

  • Free shipping all over the world

  • Reviews
  • More informations
  • Instruction
  • Video

No customer comments for the moment. Login

Write a review

AA S200/ CZ200 Quick fill with Bar manometr

AA S200/ CZ200 Quick fill with Bar manometr

Quick Fill is a device that replaces the original air tube plug. This quick fill has both gauge and filling hole for pin and there is no need to air tube unscrew the body of the rifle. We are also selling Filling adapter .

Write a review

Quick Fill is a device that replaces the original air tube plug. This quick fill has both gauge and filling hole for pin and there is no need to air tube unscrew the body of the rifle. In addition to greater comfort in the filling quick fill particularly useful when installing the regulator, since then no longer fill through regulator which eliminates the need for each fill fire several shots before the chamber pressure regulator drops in regulated value.

After installing the quick fill is the air tube with the regulator after filling immediately ready to fire. For rifles that are basically quick fill and not the gauge ( AirArms S200 ), I can offer quick fill, including already installed gauge.

New quick fill plug is longer compared to the original brass plug, by only 4mm, there is no need to worry about the problem of mounting adapters at the end of the barrel. Filling is possible from both sides, so that it is always available at least one side of the filling hole at any angle air tube to the barrel.  It is therefore not necessary to indicate the position of the air tube before mounting.

Price quick fill is 50 euro with shipping ( +12 euro for black gauge ).  In the price is included a new plug and filling pin with adapter, that can be screwed onto the hose with threaded G 1/8 internal or external, depending on whether or not to apply reduction the filling pin.

If you ordering Quick fill, make sure to mention, if you have airtube with gauge or not.

It is appropriate before reading the instructions look at the video instructions and then read the instructions for avoiding common mistakes during installation Quick fill

Unscrew airtube

Before removing plug we need drain all air from airtube. When we unscrewing plug first time, airtube may need to be attached in a vice. To avoid scratches and rotation airtube in vice is advisable to wrap the sandpaper around airtube(rough side out)  and attached it between to woods, or rubber (for the sake of the surface). The end of the jaws should be located about 3 cm from the edge of pipe where is pludge. Then use the 2 short screws (rod) and inserted them into the holes in the pludge body. Then use pliers ( wrench) for squeeze screw heads. Then you just unscrew the pludge (classic thread – unscrew counter-clockwise). Unscrewing will go really heavily. After the initial unscrew will next unscrew go much better, in some cases even by hands.

For version with pictures how to unscrew cap from airtube check CZ 200 Instruction

Change manometr

After unscrewing plug we will unscrew manometr with imbus in clockwise direction.

Put o-ring 9,25×1,78 on manometr, o-ring is delivered with the regulator. Check the cleanliness in new plug and screw in it manometr (check on him cleanliness and if not o-ring damaged). Tight strongly in hand and screw plug back into airtube (again just tightened by hand in order not to damage the O-ring).

Pin and filling

Filling pin can be screwed without reduction to airline G 1/8 male threads. With the reduction of the internal thread. Tighten the airline only for O-ring inside the pin, again by hand. The outer O-rings on the pin must be kept lubricated to prevent damage. Replacement O-rings are 2×1 and come in a bag with quick fill. When connecting pin, make sure that its larger diameter touches the wall plugs. Fill airtube slowly = open bottle filling valve slowly and only a small opening. If pressure leak out from airtube when we relief pressure in airline, remove plug again and check on the back side small-ring, if is slightly crushed between the screw head and the wall plug.

It must not be pressed to much not even to little, o-ring have to be clean and not damaged.

Shipment contains

  • Quick fill
  • Bar manometer
  • Filling pin
  • Reduction from internal thread to outside thread
  • Spare o-ring 2×1

Since Quick fill is not original part from the manufacturer’s, installation is on your own responsibility.

Instalation video

Product options note

These data is only information for us, not mandatory values. For example, if your rifle is currently set on 16J, then you can not with regulator expects higher energy than 16J. The regulator can never increase energy!

For more information, please read FAQ section or contact us by e-mail.

Output pressure we set according to requirements the power rifle with the regulator. If you want a specific output pressure so indicate that in notes for orders.

If you do not know any product options, or you are unsure so please state this in the notes for orders.