Xisico Sentry airgun regulator

Bam
search
  • Bam
  • Bam
CA-RE-031-002

The easiest and fastest installation regulator in the world.

This Airgun Regulator has a simple installation without adjustments on rifle and drilling in the tank. Installation is very easy. Just screw mounting stick on regulator, unscrew plug on airtube and push regulator on bottom airtube.

  • 250 char. max
Caliber: .177 /4.5mm
Required energy with regulator: 7,5J / 5,5 ft/lbs
Kč2,200.00
Quantity

visa

Airgun regulator for Xisico Sentry

This Airgun Regulator does not need drilling in the tank. Unscrew the air tube cap. Insert regulator on the bottom of airtube and then screw back in airtube.

Videos for installation and proper use regulator in the airgun BAM

BSA Bucaneer video Installation is very simile to Xisico Sentry

Setting output pressure on regulator

What to do when your output pressure increasing over time? This is most likely caused by dirt on o-ring on plastic screw.

In this video is shown how to remove dirt and replace o-ring. In video is used Gunpower regulator. Procedure is the same for other regulators.

Installation instructions for BAM air rifle pressure regulator

It is appropriate before reading the instructions look at the video instructions and then read the instructions for avoiding common mistakes during installation

BAM

1) Unscrewing the airtube

Before removing plug we need to drain all air from airtube, we can shoot without pellets for drain air. Unscrew coupler between airtube and barrel, then remove the plug itself. For unscrewing plug we can use mounting stick as a lever.

2) Mounting of the regulator

Screw the installation stick to the regulator and check o-ring, if it is clean and not damaged. Spray o-ring with silicone spray for preventing any damage. Push regulator to the bottom of airtube then unscrew mounting stick and screw quickfill plug back.

3) Setting pressure of airgun regulator

Altaros regulator output pressure can be set from 100bar (1450 PSI) to 150bar (2200 PSI). For a quick setting is on regulator engraved scale according to which the desired output pressure can be set. The total scale range of 100-150bar corresponds to approximately 1/2- turn. Unscrewing, or screwing setting screw more than 1 turn may result in a malfunction of the regulation and scale will not show you regulated pressure. Groove on red marked half of setting plastic screw represents pointer which shows you currently set pressure on the scale. To change the pressure on regulator, just simply rotate the set screw with the flat screwdriver in the appropriate direction according to regulator scale.
Regulator pressure scale with three different settings

4) Shipment contains

Regulator

Installation stick

Spare O-rings

Warning: 

Never unscrew regulator brass screw plugs! If you do so the regulator immediately stops working and repair is only possible at the manufacturer!

You must keep maximum cleanness in the entire pressure system (airtube and outer o-rings).

The disassembly of the internal parts regulator or failure at the exact installation procedure means that you can not claim the warranty. Since the regulator is not original part from the manufacturer’s, installation is on your own responsibility.

Results with installed regulator in air gun BAM

Unfortunately, we did not have this airgun in our workshop, so we do not have results. If someone sends them we will add them on our web.

You might also like