Kral Arms Puncher Jumbo airgun regulator
Years proven regulators (since 2010) used by thousands of satisfied customers around the world.
This regulator can be installed in most airguns which use standard airtank with thread M 18x1,5.
If you have Kral Jumbo Hi-Cap version write full name in airgun name.
With regulator is also send nylon spacer ring and two USIT o-rings with different thickness, which can be used in the case when gauge and filling pin is not in a good position.
Download instructions: HERE
- More on:
- Info
- video
- instruction
- results
The Airgun Regulator is the same as regulator for rifles gunpower, the only change is that in the package is also nylon spacer ring, which is used in the case when gauge and filling pin is not in good position. It is a simple installation without adjustments on rifle, so everything can be returned back. All you need to do is unscrew the bottle from airgun body (before screwing launch air). Then screw regulator between the bottle and airgun body. After installing the regulator NEVER fill by quick fill on the airgun, only by quick fill on regulator. For the filling you must purchase paintball coupling, which is the same as gun marauder or more. Do not use pin as lever for tightening regulator. For that is added screw in spare o-rings.
Videos for installation and proper use regulator in the airgun Kral Arms Puncher Jumbo
Installation for Daystate Wolverine B |
Video Installation for Sniper X2 bottle version which has airgun under barrel |
Installation for Royale 400 |
Video how to take regulator out of regulator body |
Setting output pressure on regulator |
What to do when your output pressure increasing over time? This is most likely caused by dirt on o-ring on plastic screw. |
Installation instruction for Airgun Kral Arms Puncher Jumbo rifle pressure regulator
It is appropriate before reading the instructions look at the video instructions and then read the instructions for avoiding common mistakes during installation Kral Arms Puncher Jumbo
Before removing plug we need to drain all air from airtank.
Mount Altaros regulator
Screw regulator on plug. We have to be sure that the regulator has in the groove the o-ring. Then screw the regulator back into the bottle and check again presence of o-ring in the neck of the bottle. Check the o-rings (cleanliness, if they are without damage) on filling pin and manometer. Pin and manometer screw-on regulator only with fingers, screw them so much that the upper larger cylinder of manometer and pin are touching regulator perimeter. Slot for pin and manometer can be changed depending on where you get more comfortable with his position, You can make a small correction and unscrew bottle little bit (no need to complete attachment to the wall). When your manometer and pin has bad position you can insert a black nylon ring in place o-ring. This changes the position after screwing.
Filling and draining air
NEVER fill air through the valve on airtube, but always fill through quick fill on regulator. If it is all ok, connect Paintball coupler and fill airtube. Be sure that paintball coupler ball lock is fall in. First filling make slowly around 2-3 bar per second. According to the type of bottle can be pressurized up to 250 bar (3600 PSI). After filling to set pressure drain air from hose and disconnect paintball coupler.
Unfortunately, Kral Arms as the only manufacturer has decided not to use standards of quick couplings and uses special ones that are not compatible with any other quick coupler on the market (Daystate, FX, Hatsan, HP compressor, etc).
For filling with our regulator it is necessary to use a standard female quick coupling.
Setting pressure of airgun regulator
Altaros regulator output pressure can be set from 100bar (1450 PSI) to 150bar (2200 PSI) and after consultation of up to 170bar (2500PSI) which corresponds to the rotation of the screw behind value 150bar so that the line of the screw is pointing to the letter R. For a quick setting is on regulator engraved scale according to which the desired output pressure can be set. The total scale range of 100-150bar corresponds to approximately 2/3 turn Unscrewing, or screwing setting screw more than 1 turn may result in a malfunction of the regulation and scale will not show you regulated pressure. Groove on red marked half of setting plastic screw represents pointer which shows you currently set pressure on the scale. To change the pressure on regulator, just simply rotate the set screw with the flat screwdriver in the appropriate direction according to regulator scale.
Regulator pressure scale with three different settings
In this picture you will find an old scale (set at 100 bar), which we no longer sell.
Shipment contains
- Altaros Regulator
- Pin and manometer
- 2 pieces 2×1 o-rings for bolt on pin
- 3 pieces 4×1 for pin and manometer
- 1 piece 19×2,5 seal between the valve and the regulator body
Warning
You must keep maximum cleanness in the entire pressure system (airtube and outer o-rings). Do not disassemble the regulator without previous approval, which will be awarded based on e-mail correspondence, where you provide the reason why it would be necessary to disassemble the regulator. In the case of a breach of this procedure you may damage the regulator function (fully assembled regulator is not simple and it is necessary to follow the correct procedure). For these reasons, the disassembly without previous consent, or failure exact installation procedure can not claim the warranty. Since regulator is not original part from the manufacturer’s, installation is on your own responsibility.
Results with installed regulator in air gun Kral Arms Puncher Jumbo
This result was done on Kram Arms Nemesis
Pellets JSB Heavy 5,52
Altaros Regulator set on 140 bar
Airtank was filled only on 200 bar, if airtank was filled on full 250 bar number of regulated shots would be higher.